2 Place System with 2 EDS O2D1-2G Kits, FPR Regulator, KF-011 (11 cu. ft.) Kevlar Wrapped Cylinder and Full-Pack


The system consists of the following items: Oxygen cylinder with Full-Pack or CMK mounting kit, the XCR primary reducing regulator, low-pressure service line, EDS Pulse Demand™ unit, breathing cannulas, face mask and tote bag. The basic EDS-O2D1-2G is a single place outlet system. Two units may be combined for a two place system such as would be used in a tandem configuration.

CGA-540 Standard North American

Duration Table (hours)
 Cylinder 

Fill   Pressure 

Volume

 Diameter 
Max.
Length
Max.
Weight
Empty

Duration in Hours
(1 Place)

 barPSI liters cu. ft.cminchcminchKg lb 10K ft  15K ft  18K ft 
 KF-011124180030310.79.273.6248 18.90  0.91 2.018.59.07.0
 KF-011128185031111.09.273.624818.900.912.019.19.27.2

The patented MH EDS (Electronic Delivery System) is a one (02D1-2G) aviation oxygen delivery device.  It is designed to deliver aviation oxygen in the most efficient, comfortable and convenient way possible.  With its user-selectable settings, apnea alarm and small size, the MH EDS is the most portable and flexible electronic digital oxygen delivery system in the world.  By providing a measured pulse of oxygen every time you breathe in, the MH EDS supplies the oxygen you need to stay alert and comfortable while flying.  In contrast to constant flow systems that waste oxygen by supplying more than your body can use, the MH EDS provides a short pulse of oxygen as you inhale, ensuring that your oxygen is used most efficiently.  Efficient oxygen delivery means you can fly further on a single oxygen refill or save space and weight with a smaller tank.  It also makes it more feasible to enjoy the advantages of oxygen while flying below the altitude where oxygen is mandated — that can mean fewer headaches, increased alertness, and feeling less exhausted when you reach your destination.  Your actual oxygen usage will be determined by your breathing rate and physiological needs at altitude.  The programmability of the MH EDS means that, unlike constant-flow oxygen systems, you can “set it and forget it”.  By automatically detecting your pressure altitude, the MH EDS can be set to start providing oxygen immediately or at a specified altitude and will automatically adjust the oxygen flow as your altitude changes.  When you’re flying, don’t you have more important things to do than adjust your oxygen flow during altitude changes?


The EDS-O2D1-2G System enables the general aviation pilot to fly at pressure altitudes up to 25,000 feet with safety and comfort.  The EDS-O2D1-2G digital Pulse-Demand™ system reduces Oxygen consumption dramatically.  Different from the “standard” constant flow systems, the EDS-O2D1-2G Pulse-Demand™ system wastes no Oxygen during the breathing cycle when oxygen is not being delivered to the lungs.  The average user will enjoy a duration increase of two to three times compared to the constant flow systems.

The built in Barometer adjusts for Altitude increase while reducing the pilots work load.

Abandoned unit auto shut off:  If you should forget to turn your EDS off after use, it will now go into auto shut-down (drawing very little power) after 3 hours of detecting no use in an attempt to save the batteries for another flight.



Included:

Items included in this EDS O2D1 Breathing System Kits

  
  
  

KF-011 Kevlar 
Oxygen Cylinder

EDS O2D1-2G Unit
EDS Cannulas
(standard tip)
00EDS-1084-00
EDS Cannulas
(flare tip)
00EDS-1084-01
EDS Face Masks
00EDS-1078-00





  Tote Bag, 12" x 12"  
 60000-0012-00
 00REG-2110-04
Regulator  
and red tubing
Full-Pack
 EDS to XCP
Coupler Ki
t
 Example system with 
KF-011 Cylinder 
 (Included Tuff-Pack or 
Full-Pack not  shown)
Not Included:
  • Oxygen - The oxygen tank is empty.

See our Full-Pack and Tuff-Pack cylinder harness & carry-caddies for these cylinders. Also see CMK cylinder hold-down kits. With the optional EDS to XCP Coupler Kit, the EDS can be used with an XCP system at the same time flow meters are being used. Also, the optional ALPS FaceMask with or without microphone is the perfect addition to any EDS system.


Product Manual:
EDS 02D1-2G and EDS 02D2-2G User Manual Rev. -1 

Related Documents:
Oxygen Cylinder Dimensions and Duration Table
EDS Oxygen Information
CAMI Testing of Pulse Oxygen Systems
CAMI Altitude Chamber Profile
Mountain High Documents Page - Manuals, specifications, articles, etc.
EDS O2D1 Specifications

Write a review

Note: HTML is not translated!
    Bad           Good

MH-00EDS-0002-02

  • Brand: Mountain High
  • Product Code: EDS-O2D1-011-2P-F
  • Availability: In Stock
  • $2,595.00


Related Products

MH-00EDS-1070-00

MH-00EDS-1070-00

Adapter to Connect EDS Unit to XCP RegulatorXCP to EDS Feed Tube for CPC type connection.EDS-XCP ada..

$10.00

MH-00EDS-1078-00

MH-00EDS-1078-00

Face Mask for EDS SystemsFace mask for the EDS pulse demand systems.  For use above 18,000..

$13.50

MH-00EDS-1084-00

MH-00EDS-1084-00

Cannula for EDS Systems - Standard Tip VersionEDS Replacement Cannula.  This item is included w..

$11.00

MH-00EDS-1084-01

MH-00EDS-1084-01

Cannula for EDS Systems - Flare Tip VersionEDS Replacement Cannula.  This item is included with..

$11.00

MH-60000-0012-00

MH-60000-0012-00

Tote BagHandy 12″ X 12″ zippered fabric tote bag for storing cannulas, face masks, flowmeters or oth..

$7.50

MH-00EDS-1050-04

MH-00EDS-1050-04

EDS O2D1-2G 1-Place Delivery System with STR Inline Regulator, 00REG-1048-04 with CPC Conn..

$925.00

MH-00EDS-0002-01

MH-00EDS-0002-01

1 Place System with EDS O2D1-2G Kit, XCR-1P-Axial Regulator, KF-011 (11 cu. ft.) Kevlar Wrapped Cyli..

$1,925.00

MH-AMSK

MH-AMSK

Alps Face MaskThe newest members of the Mountain High family of products are the MH ALPS FaceMask an..

$189.00

MH-00FAB-00xx

MH-00FAB-00xx

Full-Pack Padded Carrying Case for Portable CylindersA fully padded carry case for any of our portab..

$99.00

MH-00REG-1018-02

MH-00REG-1018-02

XCR-4P, Four Place CGA-540 Regulator FPR-REG-CGA540-no gaugeCGA-540 port for oxygen cylinder an..

$495.00

MH-00EDS-1092-00

MH-00EDS-1092-00

Cannula, E-Z Breathe-II Boom Cannula for EDS-Pulse Demand (One Touch) connector.The E-Z Breathe..

$99.00

MH-AMSK-010x-00

MH-AMSK-010x-00

All Feedtubes for ALPS MasksChoose your connection EDS or Constant Flow.Connect your ALPS mask to ou..

$5.00

MH-00EDS-1070-01

MH-00EDS-1070-01

XCP to EDS supply adapter 84 in.XCP to EDS Feed Tube for CPC type connection.EDS-XCP-Adapter, length..

$28.95

MH-00REG-1095-04

MH-00REG-1095-04

Regulator DIN 477-9 2-Stage Axial GaugeDIN 477-9 (Euro) 2-stage gauge axial regulator 4mmDIN 477-9 (..

$425.00

MH-00REG-1092-04

MH-00REG-1092-04

CGA-504 2-stage axial regulator 4mmCGA-540 2-stage axial reg. 4mm tubing.The Dual Stage regulator al..

$355.00

MH-00REG-1093-04

MH-00REG-1093-04

Regulator CGA-540 2-Stage, Axial-GaugedRegulator, Dual Stage CGA-540 x 4mm tube Axial (Gauged)CGA-54..

$415.00

Tags: 00EDS-0002-02